重复发生重新启动的 SliceService 事件后,元数据驱动器将变为可用
适用场景
- NetApp SolidFire
- Element OS 11.6 或更早版本
问题描述
在 Active IQ 错误日志 / Element UI 警报中观察到以下警报:
driveAvailable : Node ID X has 1 available drive(s).
unresponsiveService : A metadata service is not responding.
volumesDegraded : Local replication and synchronization of the following volumes is in progress. Progress of the synchronization can be seen in the Running Tasks window.
事件日志中将显示以下事件:
Restarted SliceService: previous run killed with signal 6 (SIGABRT)
如果从集群中删除了足够多的元数据驱动器,或者多个分区服务同时脱机,则可能会导致卷脱机。在这种情况下,将显示以下错误日志 / 警报:
volumesOffline : The following volumes are offline