由于文件系统问题描述、出现"sensorReadingFaed"和"ensorbleDeded"警报
适用场景
- NetApp HCI 存储节点
- NetApp SolidFire存储节点
问题描述
- NetApp SolidFire Active IQ和Element集群Web图形用户界面会显示以下警报:
sensorReadingFailed
IPMI diagnostics are currently unresponsive. Please contact support if this problem persists.
ensembleDegraded
Ensemble degraded: 1/5 database servers not connectable: {3:x.x.x.x}
- 存储节点的远程控制台上显示ext4-fs错误
[3367598.061077] EXT4-fs error (device sda2): ext4_journal_check_start:61:Detected aborted journal
[3367598.061078] EXT4-fs error (sda2): Remounting filesystem read-only xxxxxxxx
[3367598.125694] EXT4-fs error (sda3): in ext4_writepages:2878: IO failure
- 事件日志显示:
networkEvent Failed to install SSL certificate 3 { "message": "Failed to remove path=[/sf/etc/ssl/active.crt] errorCode=system:30 errorCode.message()=Read-only file system", "name": "xCheckFailure" }
platformHardwareEvent Updating BMC cold reset date 6 3 { "bmcResetDurationMinutes": 0, "bmcResetDate": "2021-05-11T23:16:41" }
unexpectedException Unexpected Exception - xCreateRepositorySourceFileFailed Failed to open and truncate /sf/apt/sources.list.new.tmp callback=[ {4:RepositorySources::packageManagerCallbackTag}] wtype=[SessionConnected] - Contact SolidFire Support. 6 3 ""
- 可以正常访问节点的BMC网页、并可访问1G/10G网络
- 按照解决方案of KB重新启动节点时,在启动期间检测到以下错误:
Version 2.17.1249. Copyright (C) 2017 American Megatrends, Inc.
NetApp H500S BIOS Date:07/10/2017 Rev:NA2.1
CPU : Intel(R) Xenom(R) CPU E5-2620 v4 @ 2.10GHz
Speed : 2.10 GHz
The IMC is operating with DDR4 2133 MHz
Port 0 : Micron_5100_XXXXXXXXXX
S.M.A.R.T Status Bad, Backup and Replace.
Press F1 to Resume...