跳转到主内容

H300E 上的上行链路摆动

Views:
58
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

适用场景

  • NetApp H300E ( H410C )
  • NIC 驱动程序版本: 4.17.13.1.
  • NIC 固件版本: 14.17.2020

问题描述

  • 10G 间歇性不可用
     
  • 所有 10G vmnic 同时关闭 - linkstate down
    [netCorrelator] 36721287us: [vob.net.vmnic.linkstate.down] vmnic vmnic4 linkstate down
    [netCorrelator] 38760463us: [vob.net.vmnic.linkstate.down] vmnic vmnic0 linkstate down
    [netCorrelator] 40864788us: [vob.net.vmnic.linkstate.down] vmnic vmnic5 linkstate down
    [netCorrelator] 42916849us: [vob.net.vmnic.linkstate.down] vmnic vmnic1 linkstate down

     
  • 驱动程序报告上行链路问题
    <NMLX_INF> nmlx5_core: vmnic4: nmlx5_en_UplinkQGetStats - (vmkdrivers/native/BSD/Network/mlnx/nmlx5/nmlx5_core/nmlx5_core_en_multiq.c:1777) not supported
    <NMLX_INF> nmlx5_core: vmnic5: nmlx5_en_UplinkQGetStats - (vmkdrivers/native/BSD/Network/mlnx/nmlx5/nmlx5_core/nmlx5_core_en_multiq.c:1777) not supported
    <NMLX_INF> nmlx5_core: vmnic1: nmlx5_en_UplinkQGetStats - (vmkdrivers/native/BSD/Network/mlnx/nmlx5/nmlx5_core/nmlx5_core_en_multiq.c:1777) not supported
    <NMLX_INF> nmlx5_core: vmnic0: nmlx5_en_UplinkQGetStats - (vmkdrivers/native/BSD/Network/mlnx/nmlx5/nmlx5_core/nmlx5_core_en_multiq.c:1777) not supported

     
  • 与 vSwitch 的连接丢失
    cpu11:2102461)WARNING: cswitch: VLAN_PortGetVLANData:397: [nsx@6876 comp="nsx-esx" subcomp="vswitch"]No vlan data for non dvs ports or ports without port group 0x2000001
    cpu11:2102461)NetVsi: 4189: Failed to get vlan tp data for port 0x2000001: Not found

     

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.