元数据驱动器的驱动器缺失会生成core.VolReadWrite
适用场景
- NetApp Element软件
- NetApp H610S
问题描述
- NetApp SolidFire Active IQ报告 警报:
- 错误代码:
sliceServiceUnhealthy
详细信息:A metadata service is unhealthy and SolidFire is attempting to migrate data away from it.
- 错误代码:
driveFailed
详细信息:1 drive(s) with state: "DriveMissing" driveID: xx.
- 错误代码:
- 此时将生成core.VolReadWrite-xx.xxxx.gz
kern.log
报告错误:
nvme nvme0: I/O 61 QID 29 timeout, aborting
nvme nvme0: I/O 567 QID 30 timeout, aborting
nvme nvme0: I/O 520 QID 31 timeout, aborting
nvme nvme0: I/O 942 QID 32 timeout, aborting
nvme nvme0: Abort status: 0x0
nvme nvme0: Abort status: 0x0
nvme nvme0: Abort status: 0x0
nvme nvme0: Abort status: 0x0
nvme nvme0: I/O 61 QID 29 timeout, reset controller
nvme nvme0: I/O 0 QID 0 timeout, reset controller
nvme nvme0: Device not ready; aborting reset
nvme nvme0: Device not ready; aborting reset
nvme nvme0: Removing after probe failure status: -19
nvme nvme0: Device not ready; aborting reset
print_req_error: 38 callbacks suppressed
print_req_error: I/O error, dev nvme0n1, sector 1464291080
print_req_error: I/O error, dev nvme0n1, sector 3122661848