由于通过中间背板进行通信,E-Series 控制器在通电期间被备用控制器置于脱机状态
适用于
E-Series
问题
RECOVERY-GURU-PROCEDURES.HTML指示OFFLINE_CTL-Recovery Failure Type Code: 28
Failure Entry 1: OFFLINE_CTL-Recovery Failure Type Code: 28
Storage array: <ARRAY_NAME>
Component reporting problem: Controller in bay B
Status: Failed
Location: Controller/Drive shelf 99, Controller in bay B
MAJOR-EVENT-LOG指示Controller reset by its alternate event
Critical,This controller's alternate is non-functional and is being held in reset,Controller,Shelf 99, Bay B,Controller in bay A
Critical,Controller redundancy lost,Controller,Shelf 99, Bay A,Controller in bay A
Informational,Controller reset by its alternate,Controller,Shelf 99, Bay B,Controller in bay A
Informational,Controller placed offline,Controller,Shelf 99, Bay B,Controller in bay A
- 在脱机之前,无法从
MAJOR-EVENT-LOG中找到其他相关错误