跳转到主内容

由于缺少驱动器,分解存储的新设置失败

Views:
Visibility:
Public
Votes:
0
Category:
asa-r2
Specialty:
hw
Last Updated:

适用于

  • ASA r2
  • 全新安装

问题

  • 在分解集群的初始化步骤中,设置步骤中的第二个节点会看到外部聚合:
[raid.foreign.failed.error]:  Disk "0n.x" has failed as the uuid on the RAID label "label" does not match with the stamped uuid "uuid"
  • 引导到 LOADER 时,驱动器可能被标记为缺失:
Device 22/0/0 (SSDx) missing
Device 23/0/0 (SSDx) missing
  • 可能会看到有关 PCIe 交换机"不可用"的消息:
[ses.status.ModuleError:ALERT]: NS224NSM16E (S/N xxxxxxxxxxxx) shelf 0 on channel 0s PCI switch error for PCI Switch 1: status not available; status not available. This element is on the rear of the shelf at the top, on shelf module (A).

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.