跳转到主内容

由于tcpdump软件包更新错误、VSC 9.7.1P2原位升级失败

适用场景

  • 适用于VMware vSphere的Virtual Storage Console (VSC) 9.7.1P2
  • 适用于 VMware vSphere 的 ONTAP 工具( OTV ) 9.8
  • 适用于VMware vSphere的ONTAP 工具(OTV) 9.10
  • 适用于VMware vSphere的ONTAP 工具(OTV) 9.11
  • 适用于VMware vSphere的ONTAP 工具(OTV) 9.12.

问题描述

无法完成 从VSC 9.7.1p2到OTV 9.11或从OTV 9.10到OTV 9.12或更高版本的OTV 9.13的原位升级 、并显示以下错误消息:

Reading package lists...
Aug 30 05:42:34: Current Installed Version: 9.7.7359: 9.7.7359
Aug 30 05:42:34: Upgrade ISO Version: 9.11.8450: 9.11.8450.
Aug 30 05:42:34: Valid upgrade version
Aug 30 05:42:34: 3072m 6144m
Aug 30 05:42:34: 3072m 6144m
Aug 30 05:42:34: 4096m
Aug 30 05:42:34: 3072m
Aug 30 05:42:34: 6144m
Aug 30 05:42:34: Succesfully persisted current xmx values..
Aug 30 05:42:43: Verifying virtual appliance upgrade...

...

Setting up tcpdump (4.99.0-2) ...
useradd: cannot open /etc/passwd
adduser: `/usr/sbin/useradd -d /nonexistent -g tcpdump -s /usr/sbin/nologin -u 106 tcpdump' returned error code 1. Exiting.
dpkg: error processing package tcpdump (--configure):
installed tcpdump package post-installation script subprocess returned error exit status 1
Setting up initramfs-tools (0.140) ...
Installing new version of config file /etc/kernel/postinst.d/initramfs-tools ...
Installing new version of config file /etc/kernel/postrm.d/initramfs-tools ...
update-initramfs: deferring update (trigger activated)
Setting up libdevmapper1.02.1:amd64 (2:1.02.175-2.1) ...
Setting up dmsetup (2:1.02.175-2.1) ...
update-initramfs: deferring update (trigger activated)
Setting up libwww-perl (6.52-1) ...
Setting up grub-common (2.04-20) ...
Installing new version of config file /etc/grub.d/00_header ...
Installing new version of config file /etc/grub.d/05_debian_theme ...

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.