跳转到主内容

由于system_ERR出现RuntimeError、升级存储控制器上的SANtricity 操作系统失败

Views:
Visibility:
Public
Votes:
0
Category:
storagegrid<a>2008658465</a>
Specialty:
sgrid
Last Updated:

适用场景

  • NetApp StorageGRID 11.4 及更高版本
  • NetApp StorageGRID 设备

问题描述

  • 升级存储控制器上的SANtricity 操作系统失败、并显示错误:

Error: Fatal installation failure - SANtricity OS staging failed with: RuntimeError: Union <<class 'SYMbol.parser.RpcAcceptedReplyBody'>> at 0xXXXXXXXXXXXX> discriminator value SYSTEM_ERR does not have a corresponding qualifier
 

  • gdu-server.log 主管理节点的显示错误:

 INFO -- gdu-server: Invalidating any staged SANtricity OS on <NODE>
 INFO -- gdu-server: 1% SANtricity OS staging done.
 INFO -- gdu-server: Staging SANtricity OS on <NODE>
 INFO -- gdu-server: 2% SANtricity OS staging done.
 INFO -- gdu-server: Staging SANtricity OS on <NODE>
 INFO -- gdu-server: WARNING -- Union <<class 'SYMbol.parser.RpcAcceptedReplyBody'>> at 0xXXXXXXXXXXXX> discriminator value SYSTEM_ERR does not have a corresponding qualifier
 INFO -- gdu-server: RuntimeError: Union <<class 'SYMbol.parser.RpcAcceptedReplyBody'>> at 0xXXXXXXXXXXXX> discriminator value SYSTEM_ERR does not have a corresponding qualifier
ERROR -- gdu-server: SANtricity OS staging failed with: SANtricity OS precheck successful.
Invalidating any staged SANtricity OS.
1% SANtricity OS staging done.
2% SANtricity OS staging done.
 ERROR -- gdu-server: SANtricity OS staging failed with: RuntimeError: Union <<class 'SYMbol.parser.RpcAcceptedReplyBody'>> at 0xXXXXXXXXXXXX> discriminator value SYSTEM_ERR does not have a corresponding qualifier (Bycast::Tasks::GduServer::SoftwareUpdate::InstallError)
  INFO -- gdu-server: Software update task complete at <TIMESTAMP>
 ERROR -- gdu-server: Failed to apply SANtricity OS to <NODE>: Fatal installation failure - SANtricity OS staging failed with: RuntimeError: Union <<class 'SYMbol.parser.RpcAcceptedReplyBody'>> at 0xXXXXXXXXXXXX> discriminator value SYSTEM_ERR does not have a corresponding qualifier
 ERROR -- gdu-server: Failure occurred during Software Update


 

  • /base-os-logs/var/log/eos-system-status 故障节点的显示错误 SYSTEM_ERR 、其中包括:

Error while running status update. Union <<class 'SYMbol.parser.RpcAcceptedReplyBody'>> at 0xXXXXXXXXXXXX> discriminator value SYSTEM_ERR does not have a corresponding qualifier
Error connecting to SYMbolAPI. Union <<class 'SYMbol.parser.RpcAcceptedReplyBody'>> at 0xXXXXXXXXXXXX> discriminator value SYSTEM_ERR does not have a corresponding qualifier

 

  • web-server-trace-log.txt 在存储控制器中、可能会显示以下输出、这意味着大约每10分钟定期重新启动一次WebServer服务:

INFO [main] c.l.a.w.s.WebServer [WebServer.java:2292] [requestId=0, deviceId=N/A] stdout: Starting web server

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.