StorageGRID设备报告存储设备存储连接已降级、并检测到光纤通道链路错误
适用场景
NetApp StorageGRID设备
问题描述
- StorageGRID网格管理器报告以下警报:
Storage appliance storage connectivity degraded
There is a problem with one or more connections between the compute controller and storage controller.
Major Event Log
在E系列控制器上、可能会报告 以下事件:
Fibre channel link errors continue (Event type 1206)
Fibre channel link errors - threshold exceeded (Event type 1207)
示例:
Event type: 1206 / 1207
Event category: Error
Priority: Informational
Event needs attention: false
Description: Fibre channel link errors continue Fibre channel link errors - threshold exceeded
Component location: Host-side: controller in bay B, port 4
Logged by: Controller in bay B
STORAGE-ARRAY-PROFILE
在E系列控制器上,可能会报告光纤通道端口已 关闭。
Host interface: Fibre
Host Interface Card(HIC): Baseboard
Channel: 2
Port: 0b
Current ID: 126/0x0
Preferred ID: 1/0xE8
NL-Port ID: 0x000000
Maximum data rate: 16 Gbps
Current data rate: 4 Gbps
Data rate control: Auto
Link status: Down
fcDump
在STATE-CAPTURE-DATA
E系列控制器上的中、错误率可能会增加:
2806-B Our Num ::...Exchange Counts...:: Num ..Link Up.. Chip LinkStat Port Port :: :: Link Bad Bad ID Logi ::Open Total Errors:: Down Char Frame 2-Src Up-Ptp 2 2 :: 2 106083407 0:: 0 0 0 3-Src Up-Ptp 2 2 :: 0 0 2969:: 0 0 0