StorageGRID 设备 SG100/1000 或 SG6000 电源故障
适用于
NetApp StorageGRID 设备 SG100/SG1000、SG6000
问题描述
StorageGRID 设备报告电源故障。
示例:
OPST (Overall Power Supply) Degraded 2019-11-05 17:44:17 CET Degraded DegradedCPSA (Compute Controller Power Supply A) Failed 2019-11-05 17:44:17 CET Failed FailedAppliance battery failed: The battery in the appliance's storage controller failed.
BMC 日志示例:
[Warning] [PSU Redundancy] [Power Supply] Redundancy Lost - Asserted
[Warning] [PSU1_Status] [Power Supply] Predictive Failure - VIN_UV_WARNING - Asserted
[Critical] [PSU1_Status] [Power Supply] Power Supply Input Lost (AC/DC) - Input Undervoltage Fault - Asserted
[Critical] [PSU1_Status] [Power Supply] Power Supply Input Lost (AC/DC) - Unit Off For Insufficient Input Voltage - Asserted
[Information] [PSU Alert] [Power Supply] State Asserted - Deasserted
[Warning] [PSU Alert] [Power Supply] State Asserted - Asserted
[Information] [PSU Redundancy] [Power Supply] Fully Redundant (Redundancy Regained) - Asserted
[Information] [PSU1_Status] [Power Supply] Predictive Failure - VIN_UV_WARNING - Deasserted
[Information] [PSU1_Status] [Power Supply] Power Supply Input Lost (AC/DC) - Input Undervoltage Fault - Deasserted
[Information] [PSU1_Status] [Power Supply] Power Supply Input Lost (AC/DC) - Unit Off For Insufficient Input Voltage - Deasserted