跳转到主内容

由于 FC 错误, StorageGRID 设备 SG6000 不属于 StorageGRID

Views:
1
Visibility:
Public
Votes:
0
Category:
storagegrid
Specialty:
esg
Last Updated:

适用场景

NetApp StorageGRID 设备 SG6000

问题描述

  • SG6000 设备停留在维护模式 / 网格前环境( PGE )中,无法启动,并且不再属于 StorageGRID 。
  • SG6000 设备报告多路径错误
  • E 系列 Major Event Log 显示路径频繁上 / 下

示例

B:10/21/20, 8:13:24 PM Fibre channel link up - Host-side: controller in bay B, port 1
B:10/21/20, 8:13:07 PMFibre channellink up - Host-side: controller in bay B, port 2
[...]
B:10/21/20, 8:09:49 PM Fibre channellink down - Host-side: controller in bay B, port 1
B:10/21/20, 8:09:49 PM Fibre channellink down - Host-side: controller in bay B, port 2

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.