由于FC错误、StorageGRID设备处于未知状态
适用场景
NetApp StorageGRID设备
问题描述
- StorageGRID设备卡在维护模式/网格前环境(PGE)下、无法启动、不再属于StorageGRID。
- E系列
Major Event Log
显示路径频繁启动/关闭 - E系列
fcDump
输出显示链路错误
示例
B:10/21/20, 8:13:24 PM Fibre channel link up - Host-side: controller in bay B, port 1
B:10/21/20, 8:13:07 PM Fibre channellink up - Host-side: controller in bay B, port 2
[...]
B:10/21/20, 8:09:49 PM Fibre channellink down - Host-side: controller in bay B, port 1
B:10/21/20, 8:09:49 PM Fibre channellink down - Host-side: controller in bay B, port 2
2800-A Our Num ::...Exchange Counts...:: Num ..Link Up.. Chip LinkStat Port Port :: :: Link Bad Bad ID Logi ::Open Total Errors:: Down Char Frame 2-Src Up-Unk ffffff 0 :: 0 0 0:: 0 0 0 3-Src Up-Unk ffffff 0 :: 0 0 0:: 0 0 0 4-Src Up-Ptp 2 2 :: 0 38150 0:: 0 0 0 5-Src Up-Ptp 2 2 :: 4 41757 920:: 0 -509716340 1323