StorageGRID 控制器意外重新启动
- Views:
- 1
- Visibility:
- Public
- Votes:
- 0
- Category:
- e-series-systems
- Specialty:
- esg<a>2009年353753</a>
- Last Updated:
适用场景
- NetApp 存储网格
- NetApp E 系列
问题描述
作为双控制器一部分的控制器意外重新启动
B:11/28/22, 2:29:34 AM (02:29:34) 29424 2014 VDD logged an error - Shelf 99, Bay B - SSID: 9, Devnum: 0x010003 LBA: 0xa3f528f8, Blocks: 0x8 - Recovered
----> Flags: 0x801 = READ: Read Operation, CURRENT: Read current data from cache
----> Recovery: 0x2 = Reconstruction used, ASC: 0x1f = IOP_FAST_TIMEOUT_ERROR, Detection: 0xf80b034b
B:11/28/22, 2:29:33 AM (02:29:33) 29423 2014 VDD logged an error - Shelf 99, Bay B - SSID: 15, Devnum: 0x010009 LBA: 0x12e0ecdc0, Blocks: 0x10 - Recovered
----> Flags: 0x801 = READ: Read Operation, CURRENT: Read current data from cache
----> Recovery: 0x2 = Reconstruction used, ASC: 0x1f = IOP_FAST_TIMEOUT_ERROR, Detection: 0xf80b034b