FabricPool 聚合数据显示不可用
适用场景
- FabricPool
- ONTAP 9
- Azure
问题描述
- Fabric Pool显示不可用
示例:
::> storage aggregate object-store show aggregate
Object Store Name Availability Mirror Type
-------------- ----------------- ------------- -----------
an30_fp_sas0 fabricpool unavailable primary
an30_fp_sas1 fabricpool unavailable primary
an31_fp_ssd0 fabricpool unavailable primary
an33_fp_ssd0 fabricpool unavailable primary
an34_fp_ssd0 fabricpool unavailable primary
an34_fp_ssd1 fabricpool unavailable primary
an35_fp_ssd0 fabricpool unavailable primary
an35_fp_ssd1 fabricpool unavailable primary
- EMS日志中显示错误
示例:
Cluster: OscLowPriThreadPool: object.store.unavailable:EMERGENCY]: Unable to connect to the object store "fabricpool" from node (address). Reason: Connection unavailable.
Cluster: ktlsd: ktls.failed:notice]: "The TLS connections have failed several times with remote host 'AA.BB.CC.DD' in IPspace '0123456789', for which the latest reason given is: OpenSSL: error:12345678:SSL routines:ssl3_get_server_certificate:certificate verify failed."
Cluster: OscHighPriThreadPool: wafl.ca.latency.threshold:notice]: Measured latency from cloud (5230 msec) more than threshold (5000 msec) (aggregate: "pn31_fp_ssd0", aggregate uuid: "XXD", object store: "bbobfabricpool")
-
无法从节点执行对象存储Ping操作。
-
节点和对象存储之间的数据包跟踪显示不可用。