跳转到主内容

为什么 StorageGRID 无法与节点通信警报未触发

Views:
Visibility:
Public
Votes:
0
Category:
storagegrid-webscale
Specialty:
HW
Last Updated:

适用于

NetApp StorageGRID

问题解答

无法与节点通信警报从 Prometheus 查找以下属性。
  • (count(up != 1) without (job) > 0) - 检查节点是否无法访问或脱机

  • unless on(instance) storagegrid_administratively_down == 1 - 检查节点是否已被管理员关闭

管理性关闭属性确定节点关闭是否在预期之中。该属性是在以下异常期间设置的。
  • 处于维护模式
  • 正在退役
  • 正在进行克隆操作
  • 从 BMC 断电或物理断电
  • 从 CLI 关闭
如果 administratively down 属性为 true,则不会触发警报。

追加信息

additionalInformation_text
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.