StorageGRID 警报更换后存储设备存储连接降级
适用于
- NetApp StorageGRID
- NetApp SG6000 设备
问题描述
- StorageGRID UI 在 HBA 或计算节点更换后报告
Storage appliance storage connectivity degraded。 - E 系列后端上的所有端口都是
UP,在state-capture-data.txt>fcDump中没有递增的光纤通道错误 - 计算节点 HBA 上的所有端口在
/var/local/log/kern.log中报告UP:localhost kernel: [12.00] lpfc 0000:b0:00.0: 0:1303 Link Up Event x1 received Data: x1 x0 x80 x0 x0 x0 0localhost kernel: [13.00] lpfc 0000:b0:00.1: 1:1303 Link Up Event x1 received Data: x1 x0 x80 x0 x0 x0 0localhost kernel: [14.00] lpfc 0000:b0:00.2: 2:1303 Link Up Event x1 received Data: x1 x0 x80 x0 x0 x0 0localhost kernel: [15.00] lpfc 0000:b0:00.3: 3:1303 Link Up Event x1 received Data: x1 x0 x80 x0 x0 x0 0
- 在 StorageGRID
base-os-logs/command_results.txt中缺少路径:command `multipath -ll` completed with code 0. Output: StorageGRID-obj-00 (xxxxxxxx) dm-3 NETAPP,INF-01-00 size=22T features='3 queue_if_no_path pg_init_retries 50' hwhandler='1 alua' wp=rw |-+- policy='service-time 0' prio=50 status=active | |- 17:0:0:222 sdak 66:64 active ready running | `- 18:0:0:222 sdbs 68:96 active ready running `-+- policy='service-time 0' prio=10 status=enabled `- 15:0:0:222 sdc 8:32 active ready running
storage-array-profile在 E-Series ASUP 报告中 未关联主机端口:STORAGE ARRAY Default type: Factory Default Unassociated Host Ports Host Port: 10:00:00:00:00:00:00:d7 Default Host Cluster Host: StorageGRID Appliance Host type: Linux DM-MP (Kernel 3.10 or later) Interface type: Fibre Channel Host port identifier: 10:00:00:00:00:00:00:d9 Alias: 0x Host port identifier: 10:00:00:00:00:00:00:da Alias: 0x Host port identifier: 10:00:00:00:00:00:00:d8 Alias: 0x