跳转到主内容

StorageGRID 设备 NIC 故障 - AutoSupport 消息

Views:
2
Visibility:
Public
Votes:
0
Category:
storagegrid
Specialty:
sgrid
Last Updated:

适用于

  • NetApp StorageGRID
  • 软件版本 11.7 +

事件摘要

  • StorageGRID Grid Manager 报告以下警报: 检测到设备网卡故障 – 检测到设备中的网络接口卡 (NIC) 有问题
  • ASUP 生成的警报,以防发生以下情况:

StorageGRID Notification from GRIDID(HARDWARE FAILURE - Component: NIC, Slot: hic3, PartNumber: X1158A)
nicName: hic3, nicDescription: ConnectX-6 Lx EN adapter card, 25GbE, Dual-port SFP28, PCIe 4.0 x8, No Crypto, nicSerialNumber: MTXXXXXXXX3R, nicFirmwareVersion: 26.39.1002 (MT_0000000531), componentMarketingPartNumber: X90-SG6000-HBA-FC, component3x5PartNumber: 106-00289, hardwarePlatform: SGF6112

验证

  1.   登录到 StorageGRID Grid Manager,并确认存在以下警报:

Appliance NIC fault detected – A problem with a network interface card (NIC) in the appliance was detected

  1. 使用以下命令验证在 hic 上看到的错误。
    1. ifconfig <hic>
    2. ethtool -S <hic>

解决方法

  1. 在 StorageGRID Grid Manager 中,导航到 Support > Diagnostics  > Appliance hardware component temperatures ,然后查找 NIC 组件。
    • NIC 端口的地址如下:
      • 0000:30:02_0_0000:31:00_0
      • 0000:30:02_0_0000:31:00_1
      • 0000:b0:02_0_0000:b1:00_0
      • 0000:b0:02_0_0000:b1:00_1
  2. 如果发现上述警报,请按照"NetApp StorageGRID NIC 故障检测并触发温度警报"下的说明解决问题。
  3. 如果上述步骤无法解决问题,则可以尝试重新拔插 NIC。
    • 请参见设备的维护说明以了解详细步骤。
  4. 解决方案可能需要更换部件。请联系NetApp 技术支持或登录到 NetApp 支持站点以创建案例。请参阅本文以获得进一步帮助。

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.