跳转到主内容

StorageGRID 设备计算控制器因 MCERR 需要注意

Views:
37
Visibility:
Public
Votes:
0
Category:
storagegrid
Specialty:
sgrid
Last Updated:

适用于

NetApp StorageGRID 设备

问题描述

  • 检测到 Appliance compute controller needs attention 警报
  • storagegrid_crash_dmesg.log 表示硬件错误

{1}[Hardware Error]: Hardware error from APEI Generic Hardware Error Source: 0
{1}[Hardware Error]: It has been corrected by h/w and requires no further action
{1}[Hardware Error]: event severity: corrected
{1}[Hardware Error]:  Error 0, type: corrected
{1}[Hardware Error]:   section_type: memory error
{1}[Hardware Error]:   physical_address: 0x000000267a8e0340
{1}[Hardware Error]:   physical_address_mask: 0x00003fffffffffc0
{1}[Hardware Error]:   node: 3 card: 2 module: 0 rank: 1 device: 5 row: 40839 column: 176 
{1}[Hardware Error]:   error_type: 2, single-bit ECC
{1}[Hardware Error]:   DIMM location: NODE 2 CPU1_F0 
mce: [Hardware Error]: Machine check events logged
EDAC skx MC3: HANDLING MCE MEMORY ERROR
EDAC skx MC3: CPU 0: Machine Check Event: 0 Bank 255: 940000000000009f
EDAC skx MC3: TSC 0 
EDAC skx MC3: ADDR 267a8e0340 
EDAC skx MC3: MISC 0 
EDAC skx MC3: PROCESSOR 0:50657 TIME 1655421018 SOCKET 0 APIC 0

  • SEL_TEXT.txt 由 BMI 日志和报告 > IPMI 事件日志 > 文本文件类型 > 下载事件日志 收集,表示 Uncorrectable Error

Severity   Sensor Name         Sensor Type            Description
[Critical]      [CATERR]      [Processor]   Machine Check Exception (MCERR) - Asserted
[Critical]      [CATERR]      [Processor]   Machine Check Exception (MCERR) - Asserted
[Warning]      [Additional MCE Error]   [OEM Record C2]   ManufacturerID:001C4C, Extra Information : 0 MSCOD:0010 MCACOD:0134
[Critical]      [MCERR]      [Processor]   Uncorrectable Error - Machine Check Error: Bank 1/CPU 0/Core 1 - Asserted

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.