StorageGRID设备计算控制器电源出现问题
适用于
- NetApp StorageGRID
- StorageGRID 设备:SG1XX、SG1XXX 和 SG6XXX
问题描述
- StorageGRID Grid Manager 报告计算控制器电源的以下警报之一:
Appliance compute controller power supply A has a problemCompute controller power supply A: Unknown
bycast.log中的/var/local/log/显示了电源的以下故障消息:
Nov 22 20:01:39 <node_name> ADE: |16701338 0082291168 RSMR UPDL 2022-11-22T20:01:39.684890| WARNING 0240 CCST: IPMI device PSU1_Status reports non-OK status 'Presence detected' 'Predictive Failure' 'Power Supply input lo
Nov 22 20:01:39 <node-name> ADE: |16701338 0082291168 RSMR UPDL 2022-11-22T20:01:39.684911| WARNING 0240 CCST: IPMI device PSU Redundancy reports non-OK status 'Redundancy Lost'
- gemini-system-status 文件夹中的
status.json文件在基本操作系统中/var/local/gemini-system-status或在日志捆绑包中\var\local\gemini-system-status报告以下状态:
"name": "PSU1_Status",
"type": "Power Supply",
"reading": "N/A",
"units": "N/A",
"event": "'Presence detected' 'Predictive Failure' 'Power Supply input lost"