由于缺少磁盘、StorageGRID SGF6112安装失败
适用场景
- NetApp StorageGRID
- SGF6112设备
问题描述
- 新安装期间观察到错误:“一个或多个驱动器丢失或无响应,并且没有足够的良好驱动器来定位和启动现有的 StorageGRID 安装。您必须纠正此情况。丢失或无响应的驱动器是 HDD0X”
- (已移除插入设备的所有已知良好的驱动器)。
- 受影响的存储节点处于预 GRID 环境 (PGE) 状态,无法完成安装。
- 在LumberjackPGE日志中>
/tmp/lumberjack/PGE:sgalocalstoragetool.log报告未找到驱动器:
2025-04-08|12:47:41|notice|load_g_slot_to_bdev | 2275| no drive found for slot HDD04
2025-04-08|12:47:41|notice|load_g_slot_to_bdev | 2275| no drive found for slot HDD05
sgalst-last-recovery.json 报告两个托架中缺少两个驱动器:
"HDD04:state": "missing",
"HDD04:warning:missing_or_unresponsive_drive": "true",
"HDD05:state": "missing",
"HDD05:warning:missing_or_unresponsive_drive": "true",provision.log报告正在跳过安装:
[2025-04-08 12:27:00+00:00 SGA] Boot action from sgalocalstoragetool: 'halt_in_installer_with_clobber_warning'[2025-04-08 12:27:00+00:00 SGA] Clobber warning token from sgalocalstoragetool: 'missing_or_unresponsive_drive'[2025-04-08 12:27:00+00:00 SGA] Clobber warning data from sgalocalstoragetool: 'HDD04 HDD05 '[2025-04-08 12:27:00+00:00 SGA] Local RAID is missing or broken, or a reboot is needed; not mapping volumes[2025-04-08 12:27:14+00:00 SGA] Skipping StorageGRID install check because a platform issue was detect during boot[2025-04-08 12:27:15+00:00 SGA] [2025-04-08T12:27:14.988] - WARNING -- Failed to get SG OS LUN path. Device /dev/mapper/StorageGRID-SG-OS does not exist[2025-04-08 12:27:15+00:00 SGA] [2025-04-08T12:27:14.988] - INFO -- Not loading synced data from SG OS LUN. Device does not exist