适用场景

适用于 Windows 的 SnapCenter 插件( SCW )

问题描述

Hyper-V 直通磁盘的 SnapCenter 磁盘枚举失败 [VHD ( x ) ]
 
SCW日志显示、由于制造商类型的原因、磁盘被忽略:
 2022-03-23T21:52:00.4667762-04:00 Information SDW PID=[10180] TID=[3076] Ignoring disk with DiskId: \\?\scsi#disk&ven_msft&prod_virtual_disk#000000#{53f56307-b6bf-11d0-94f2-00a0c91efb8b} Because the disk manufacturer is unknown 2022-03-23T21:52:00.4667762-04:00 Information SDW PID=[10180] TID=[3076] Ignoring disk with DiskId: \\?\scsi#disk&ven_msft&prod_virtual_disk#000001#{53f56307-b6bf-11d0-94f2-00a0c91efb8b} Because the disk manufacturer is unknown 2022-03-23T21:52:00.4667762-04:00 Information SDW PID=[10180] TID=[3076] Ignoring disk with DiskId: \\?\scsi#disk&ven_msft&prod_virtual_disk#000002#{53f56307-b6bf-11d0-94f2-00a0c91efb8b} Because the disk manufacturer is unknown 2022-03-23T21:52:00.4667762-04:00 Information SDW PID=[10180] TID=[3076] Ignoring disk with DiskId: \\?\scsi#disk&ven_msft&prod_virtual_disk#000003#{53f56307-b6bf-11d0-94f2-00a0c91efb8b} Because the disk manufacturer is unknown 2022-03-23T21:52:00.4667762-04:00 Information SDW PID=[10180] TID=[3076] Ignoring disk with DiskId: \\?\scsi#disk&ven_msft&prod_virtual_disk#000004#{53f56307-b6bf-11d0-94f2-00a0c91efb8b} Because the disk manufacturer is unknown 2022-03-23T21:52:00.4667762-04:00 Information SDW PID=[10180] TID=[3076] Ignoring disk with DiskId: \\?\scsi#disk&ven_msft&prod_virtual_disk#000005#{53f56307-b6bf-11d0-94f2-00a0c91efb8b} Because the disk manufacturer is unknown 2022-03-23T21:52:00.4667762-04:00 Information SDW PID=[10180] TID=[3076] Ignoring disk with DiskId: \\?\scsi#disk&ven_msft&prod_virtual_disk#6&3ab5a3ec&0&000000#{53f56307-b6bf-11d0-94f2-00a0c91efb8b} Because the disk manufacturer is unknown

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.