跳转到主内容

使用多个SVM SVM挂载适用于Oracle的SnapCenter插件失败

Views:
12
Visibility:
Public
Votes:
0
Category:
snapcenter
Specialty:
snapx<a>2010041030</a>
Last Updated:

适用场景

  • Snap塞 纳服务器4.8或更高版本
  • 适用于Oracle的SnapCenter插件

问题描述

尝试挂载或克隆备份时、系统会尝试使用错误的NFS LIF地址、并在日志中显示以下消息:

scu日志:

2024-05-21T15:14:46.0701094-07:00 DEBUG: SCUPlugin: 137: SCU::Utils::Logger::set_error_and_log_with_level(): Failed to execute the command 'mount -t nfs -o rw,relatime,vers=3,rsize=65536,wsize=65536,namlen=255,acregmin=0,acregmax=0,acdirmin=0,acdirmax=0,hard,proto=tcp,timeo=600,retrans=2,sec=sys,mountvers=3,mountport=635,mountproto=tcp,local_lock=none 10.99.160.129:/Sc9e13706b-923c-40fd-ae8e-76db2f6bdebd /oradata/ORION/redo01_RPTSDR', command exited with value 32.
2024-05-21T15:14:46.0701313-07:00 DEBUG: SCUPlugin: SCU::Utils::CommandHelper::execute_command(): Messages in command error stream: mount.nfs: Connection timed out
2024-05-21T15:14:46.0701475-07:00 ERROR: SCUPlugin: 191: SCU::Utils::Logger::set_and_log_error(): Mounting the filesystem '/oradata/ORION/redo01_RPTSDR' failed, reason: mount.nfs: Connection timed out
2024-05-21T15:14:46.0702155-07:00 DEBUG: SCUPlugin: SCU::Utils::CommandHelper::execute_command(): Running command 'systemctl' with timeout 600

 

SMCORE或SAL日志:

2024-05-16T22:19:18.5181414-07:00 Verbose SAL PID=[3872] TID=[6272] SDGetNetworkInterfacesResponse :
SDGetNetworkInterfacesResult : Network Interface : Name - SVM_Lif01_dmz_nfs01, Address - 10.99.160.129, StorageSystem - SVM_Lif01, Protocols - Nfs
SDGetNetworkInterfacesResult : Network Interface : Name - SVM_Lif01_dnfs1_01, Address - 10.99.162.6, StorageSystem - SVM_Lif01, Protocols - Nfs,Cifs,fcache
SDGetNetworkInterfacesResult : Network Interface : Name - SVM_Lif01_nfs_data_01, Address - 10.99.163.134, StorageSystem - SVM_Lif01, Protocols - Nfs,Cifs,fcache
SDGetNetworkInterfacesResult : Network Interface : Name - SVM_Lif01_nfs_data_02, Address - 10.99.163.135, StorageSystem - SVM_Lif01, Protocols - Nfs,Cifs,fcache
 
(稍后在SAL/SMCORE日志中)
 
2024-05-16T22:19:18.5337664-07:00 Verbose SAL PID=[3872] TID=[6272] Replacing vserver name of clone.LogicalPath: 10.99.164.134:/Scad9c7cfa-0459-4b96-ab7f-22f48616634e with IP address 10.99.160.129

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.