重新启动 SCV 后, SnapMirror 更新失败,并显示 " 找不到 SnapMirror 目标 " 。
适用场景
- 适用于 VMware vSphere 的 SnapCenter 插件( SCV )
- 重新启动 SCV 后
- 已配置 SnapMirror
- 辅助存储器添加到选择控制阀的存储系统中
问题描述
- 选择控制阀作业检测到SnapMirror错误:
Unable to find SnapMirror destination(s). Error: No SnapMirror relationships were found. Resolution: Please make sure that secondary storage systems are registered and host can resolve them correctly.Unable to find SnapMirror destination for the source volume(s) 10.10.10.10 : volume1
- 中记录了以下错误
ProtectionServices-[date].log
2021-10-15 10:34:06.543 +09:00 [DBG] [Storage] [TID:6] [RID:] [CID:] [JID:-1] Connecting to svm2.demo.netapp.com via HTTPS
2021-10-15 10:34:36.555 +09:00 [ERR] [Storage] [TID:6] [RID:] [CID:] [JID:-1] API invoke failed. at NetApp.DataProtection.Storage.CommandAPI.ConnectNcController.ConnectHTTP(IController filer, DataProtectionCredential credentials)
at NetApp.DataProtection.Storage.CommandAPI.ConnectNcController.Connect(String name)
2021-10-15 10:34:36.555 +09:00 [ERR] [Storage] [TID:6] [RID:] [CID:] [JID:-1] Failed to run a command NetApp.DataProtection.Storage.CommandAPI.ConnectNcController, Exception:API invoke failed.
API invoke failed.
2021-10-15 10:34:36.555 +09:00 [DBG] [Storage] [TID:6] [RID:] [CID:] [JID:-1] GetResource exception in initializor : API invoke failed.. API invoke failed.. Connection timed out Connection timed out
2021-10-15 10:34:36.555 +09:00 [INF] [Storage] [TID:6] [RID:] [CID:] [JID:-1] Begin GetSALStorageConnectionRetry
2021-10-15 10:34:36.555 +09:00 [INF] [Storage] [TID:6] [RID:] [CID:] [JID:-1] End GetSALStorageConnectionRetry