跳转到主内容

SRA 测试故障转移失败,错误为:无法创建副本设备的快照。无法将设备呈现给 ESX 主机

Views:
128
Visibility:
Public
Votes:
0
Category:
ontap-storage-replication-adapter
Specialty:
virt
Last Updated:

适用于

  • 适用于 VMware 的 ONTAP 工具 (OTV) 9.x
  • NetApp Storage Replication Adapter (SRA) 9.x
  • VMware Site Recovery Manager (SRM)

问题描述

SRM 测试故障转移失败,错误为:

Error - Failed to create snapshots of replica devices. Failed to present device to ESX host.

在调查期间,发现 SRA 从 SRM 接收输入,并创建一个名为 `testfailover_igroup_domain-c2033` 的 igroup,其中包含所有启动器。但是,添加启动器 `10:00:2a:e9:e8:80:02:8e` 时失败。

SRA:

2025-07-24T04:26:52,585Z (DEBUG) - No matching igroup found. Creating testfailover_igroup_domain-c20332025-07-24T04:26:52,770Z (DEBUG) - Unable to online/map LUN. Failed with exception Caused by: AbstractController: id: 8acbcc79-384a-11e6-bb0f-90e2bac61d78name: SVM_Name ip address: 10.x.x.x failed to add initiator 10:00:2A:E9:E8:80:02:8E to the igroup testfailover_igroup_domain-c2033, specifically com.netapp.offtap3.ontap.ApiFailedException: Initiator group "testfailover_igroup_domain-c2033" already contains initiator "10:00:2a:e9:e8:80:02:8e". (errno=9008).  Caused by: Initiator group "testfailover_igroup_domain-c2033" already contains initiator "10:00:2a:e9:e8:80:02:8e". (errno=9008)

2025-07-24T04:26:52,770Z (DEBUG) - Unable to online/map LUN. Failed with exception Caused by: AbstractController: id: 8acbcc79-384a-11e6-bb0f-90e2bac61d78name: SVM_Name ip address: 10.x.x.x failed to add initiator 10:00:2A:E9:E8:80:02:8E to the igroup testfailover_igroup_domain-c2033, specifically com.netapp.offtap3.ontap.ApiFailedException: Initiator group "testfailover_igroup_domain-c2033" already contains initiator "10:00:2a:e9:e8:80:02:8e". (errno=9008)

2025-07-24T04:26:52,777Z (DEBUG) - Failed to present SAN device to ESX host; no matching igroup found in request

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.