跳转到主内容

AIQUM 9.7P1 在 MetroCluster 采集上失败

Views:
6
Visibility:
Public
Votes:
2
Category:
oncommand-unified-manager
Specialty:
om
Last Updated:

适用场景

  • ActiveIQ Unified Manager 9.7P1 

问题描述

由于 Duplicate entrynodeswitchconnection  MetroCluster 处于开启状态,采集在采集期间失败

有关此错误的详细信息,请参见 /var/log/ocum/ocumserver.log

2020-10-07 13:23:43,318 ERROR [oncommand] [reconcile-4] [clustername(incremental@13:23:41.368)] [c.n.dfm.collector.OcieJmsListener] Error during MetroCluster component monitoring : could not execute batch
com.netapp.dfm.ontap.outbound.zapi.OcumMonitoringFailedException: could not execute batch
         at deployment.dfm-app.war//com.netapp.dfm.impl.mcc.MccFabricConfigDiscoveryHandler.discoverTopology(MccFabricConfigDiscoveryHandler.java:108)
         at deployment.dfm-app.war//com.netapp.dfm.impl.mcc.MccFabricConfigDiscoveryHandler$$FastClassBySpringCGLIB$$6c3297f.invoke(<generated>)


Caused by: java.sql.BatchUpdateException: (conn=94) Duplicate entry '6458966-2130005007' for key 'nodeswitchconnection.NodeSwitchConnection_NodeIdSwitchId_UQ'
         at org.mariadb//org.mariadb.jdbc.MariaDbStatement.executeBatchExceptionEpilogue(MariaDbStatement.java:288)
         at org.mariadb//org.mariadb.jdbc.ClientSidePreparedStatement.executeBatch(ClientSidePreparedStatement.java:301)
         at deployment.dfm-app.war//org.apache.commons.dbcp.DelegatingStatement.executeBatch(DelegatingStatement.java:297)
         at deployment.dfm-app.war//org.apache.commons.dbcp.DelegatingStatement.executeBatch(DelegatingStatement.java:297)
         at deployment.dfm-app.war//org.hibernate.engine.jdbc.batch.internal.BatchingBatch.performExecution(BatchingBatch.java:110)
         ... 57 common frames omitted
Caused by: java.sql.SQLIntegrityConstraintViolationException: (conn=94) Duplicate entry '6458966-2130005007' for key 'nodeswitchconnection.NodeSwitchConnection_NodeIdSwitchId_UQ'
         at org.mariadb//org.mariadb.jdbc.internal.util.exceptions.ExceptionMapper.get(ExceptionMapper.java:235)
         at org.mariadb//org.mariadb.jdbc.internal.util.exceptions.ExceptionMapper.getException(ExceptionMapper.java:171)
         at org.mariadb//org.mariadb.jdbc.MariaDbStatement.executeBatchExceptionEpilogue(MariaDbStatement.java:285)
         ... 61 common frames omitted
Caused by: java.sql.SQLException: Duplicate entry '6458966-2130005007' for key 'nodeswitchconnection.NodeSwitchConnection_NodeIdSwitchId_UQ'
         at org.mariadb//org.mariadb.jdbc.internal.protocol.AbstractQueryProtocol.readErrorPacket(AbstractQueryProtocol.java:1594)
         at org.mariadb//org.mariadb.jdbc.internal.protocol.AbstractQueryProtocol.readPacket(AbstractQueryProtocol.java:1453)
         at org.mariadb//org.mariadb.jdbc.internal.protocol.AbstractQueryProtocol.getResult(AbstractQueryProtocol.java:1415)
         at org.mariadb//org.mariadb.jdbc.internal.protocol.AsyncMultiRead.call(AsyncMultiRead.java:142)
         at org.mariadb//org.mariadb.jdbc.internal.protocol.AsyncMultiRead.call(AsyncMultiRead.java:68)
         ... 4 common frames omitted

 

/var/log/ocum/au.log
2020-10-07 13:23:42,078 INFO  [oncommand] [collection-completion-0] [c.n.d.i.m.MccFabricConfigDiscoveryHandler] MetroCluster discovery started for clustername at 13:23:42.
2020-10-07 13:23:42,513 ERROR [oncommand] [collection-completion-0] [c.n.d.i.m.MccFabricConfigDiscoveryHandler] MetroCluster monitoring failed for clustername at 13:23:42.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.