由于"无法读取页面"、无法在UM中启动MySQL
适用场景
- ActiveIQ Unified Manager (UM) 9.6及以上
- OnCommand 统一管理器(UM) 9.5及更低版本
问题描述
- 无法在UM中启动MySQL进程
- MySQL
error.log
:
InnoDB: Page may be a transaction system page
2022-09-22T13:39:41.717356Z 1 [ERROR] [MY-011906] [InnoDB] Database page corruption on disk or a failed file read of page [page id: space=0, page number=5]. You may have to recover from a backup.
InnoDB: Page may be a transaction system page
2022-09-22T13:39:41.799035Z 1 [ERROR] [MY-011899] [InnoDB] [FATAL] Unable to read page [page id: space=0, page number=5] into the buffer pool after 100 attempts. The most probable cause of this error may be that the table has been corrupted. Or, the table was compressed with with an algorithm that is not supported by this instance. If it is not a decompress failure, you can try to fix this problem by using innodb_force_recovery. Please see http://dev.mysql.com/doc/refman/8.0/en/ for more details. Aborting...
2022-09-22T13:39:41.799067Z 1 [ERROR] [MY-013183] [InnoDB] Assertion failure: buf0buf.cc:3924:ib::fatal triggered thread 139803704239872