跳转到主内容

冷存储vMotion失败、热存储vMotion成功

Views:
5
Visibility:
Public
Votes:
0
Category:
virtual-storage-console-for-vmware-vsphere<a>2009924100</a>
Specialty:
virt
Last Updated:

适用场景

  • ONTAP 9.10及更高版本
  • VMware vSphere 7.0.3
  • 适用于VMware vSphere的ONTAP工具9.13.
  • 适用于VMware VAai 2.0.1-15和2.0.1-16的NetApp NFS插件
  • NFS 4.1

问题描述

将ONTAP 9.12.1P5升级到9.12.1P10后、卷或FlexGroup之间的冷存储vMotion (同一SVM)失败、并显示错误"NfcErrorCode"、值= 23。
 
0000-00-00T00:00:00.000Z info vpxd[11111] [Originator@2222 sub=Default opID=lrtxyw8r-3333333-auto-44vx-vx:55555555-66] [VpxLRO] -- ERROR task-77777777 -- vm-888888 -- vim.VirtualMachine.relocate: vim.fault.NetworkCopyFault:--> Result:--> (vim.fault.NetworkCopyFault)
{​​-->    faultCause = (vmodl.MethodFault) null,
-->    faultMessage = (vmodl.LocalizableMessage)
[-->       (vmodl.LocalizableMessage)
{​​-->          key = "",-->          arg = (vmodl.KeyAnyValue)
[-->             (vmodl.KeyAnyValue)
{​​-->                key = "DestFile",-->                value = "/vmfs/volumes/xxxxxxxxxx/yyyyyyy/name.vmdk"-->            
}​​,-->             (vmodl.KeyAnyValue) {​​-->                key = "NfcErrorCode",-->         value = 23-->            
}​​,-->             (vmodl.KeyAnyValue) {​​-->                key = "NfcErrorCodeString",-->                  value = "NFC_ASYNC"-->            
}​​,-->             (vmodl.KeyAnyValue) {​​-->                key = "NfcErrorString",-->             value = "The request will complete asynchronously"-->            
}​​-->         
],-->          message = ""-->      
}​​-->   
],-->    file = "/vmfs/volumes/xxxxxxxxxx/yyyyyyy/name.vmdk"-->   
msg = "Could not complete network copy for file /vmfs/volumes/xxxxxxxxxx/yyyyyyy/name.vmdk"--> }​​
 
 
vCenter错误:
 
Operation Failed!
 
clipboard_ec3c8765aa392534199547ddfc76f4a4e.png
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.