搜索
- https://kb-cn.netapp.com/on-prem/ontap/MC/MC-KBs/ATTO_FibreBridge_is_not_secured_-_Active_IQ_Wellness_Risk适用场景 ONTAP 9.5 及更高版本 ATTO 7500N FibreBridge ATTO 7600N FibreBridge 风险摘要 如果 ATTO 7500N/7600N FibreBridge 未在安全模式下运行,则它可能会意外重新启动。NetApp 强烈建议在安全模式下使用 ONTAP 9.5 及更高版本运行 ATTO 7500N/7600N FibreBridge 。
- https://kb-cn.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/Identify_FlexCache_origin_volumes_over_80_utilized_Active_IQ_Wellness_Risk适用场景 9.15.1P1 9.15.1P1 及更高版本 启用了回写的FlexCache 风险摘要 如果在FlexCache卷上启用了回写、并且初始卷的容量超过80%、则性能会下降、因为ONTAP不会授予RW委派、从而导致回写未被利用。
- https://kb-cn.netapp.com/on-prem/ontap/OHW/OHW-KBs/Active_IQ_Wellness_Risk__AFF_FAS80x0_SP_ethernet_switch_firmware_should_be_upgraded_to_Version3AFF 系统: AFF8080 , AFF8060 , AFF8040 , AFF8020 FAS 系统: FAS8080 , FAS8060 , FAS8040 , FAS8020 Active IQ 数字顾问健康检查 错误 911759 错误 1312030 控制器的服务处理器( Service Processor , SP )固件已更新。但是, Active IQ 运行状况监控表明,您的 S...AFF 系统: AFF8080 , AFF8060 , AFF8040 , AFF8020 FAS 系统: FAS8080 , FAS8060 , FAS8040 , FAS8020 Active IQ 数字顾问健康检查 错误 911759 错误 1312030 控制器的服务处理器( Service Processor , SP )固件已更新。但是, Active IQ 运行状况监控表明,您的 SP 的内部以太网交换机需要手动干预才能完成更新过程。 运行 sp status -d并搜索以下日志: Oct 6 19:27:57 (none) kernel: FIFO overrun: 4479c - call vsc452mac_reset_rx_engine() Oct 6 19:27:57 (none) kernel: FIFO overflow: 4479c - call vsc452mac_reset_rx_enginf() Oct 6 19:27:57 (none) kernel: exiting vsc452mac_reset_rx_engine%%% GDB_TRACE:
- https://kb-cn.netapp.com/data-mgmt/AIQUM/AIQUM_Kbs/API-S_End_of_Support_notification适用场景 OnCommand API服务(API-S) 风险摘要 OnCommand API服务已停止支持 完全支持结束 NetApp为某个版本的软件产品提供完全支持的时间段、包括:技术支持、根发生原因 分析、安全漏洞评估、文档和在线提供的软件以及服务更新(P版本)。 产品特定功能版本的有限支持终止以及过渡到自助服务支持的日期。缩写为EOVS 停止完全支持 停止版本支持 终止可用性 2021年4月...适用场景 OnCommand API服务(API-S) 风险摘要 OnCommand API服务已停止支持 完全支持结束 NetApp为某个版本的软件产品提供完全支持的时间段、包括:技术支持、根发生原因 分析、安全漏洞评估、文档和在线提供的软件以及服务更新(P版本)。 产品特定功能版本的有限支持终止以及过渡到自助服务支持的日期。缩写为EOVS 停止完全支持 停止版本支持 终止可用性 2021年4月30日 2020年5月31日 2020年5月14日
- https://kb-cn.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/McAfee_scanner_removes_AutoSupport_sections_when_data_size_limit_is_exceeded适用场景 ONTAP 9 AutoSupport 传输 SMTP 适用于电子邮件服务器的 McAfee 安全性 问题描述 AutoSupport 事件缺少部分 存在一个包含以下内容的 " 警告 " AutoSupport 部分: McAfee - DENIAL OF SERVICE A denial of service protection limit was exceeded. Context...适用场景 ONTAP 9 AutoSupport 传输 SMTP 适用于电子邮件服务器的 McAfee 安全性 问题描述 AutoSupport 事件缺少部分 存在一个包含以下内容的 " 警告 " AutoSupport 部分: McAfee - DENIAL OF SERVICE A denial of service protection limit was exceeded. Context: 'xxxxxxxxxxxxxxxxxxxxxxxxx' Reason: The data size limit was exceeded Limit: 20 MB For further information, contact your system administrator. Copyright 1999-2014 McAfee, Inc. All Rights Reserved. http://www.mcafee.com
- https://kb-cn.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/Fpolicy_EAGAIN_errors_seen_in_fpolicy.log_in_ONTAPFpolicy日志中存在EAGAIN错误。EMS或事件日志显示与EAGAain错误相关的报告错误:[filer1:fpolicy:fpolicy.eagon.write:note]:
- https://kb-cn.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/Cloud_Insights_Workload_Security__Fpolicy_Best_Practice_and_Recommendations本指南对于确保您查看Cloud Secure 和NetApp的最佳实践至关重要。
- https://kb-cn.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/Veritas_Fpolicy_Best_Practice_and_Recommendations以下文章概述了与Veritas准则结合创建的Verataas Data Insight FPolicy应用程序的最佳实践
- https://kb-cn.netapp.com/on-prem/ontap/MC/MC-KBs/SyncMirror_resync_speed_setting_-_Active_IQ_Wellness_Risk适用场景 ONTAP 9 MetroCluster 风险摘要 在SyncMirror 丛出现故障或初始化SyncMirror 关系时、SyncMirror 重新同步运行速度可能较慢。 作为最佳实践、对于高于ONTAP 9.5的版本、NetApp建议在AFF/ASA平台上将此选项设置为4。 从ONTAP 9.11.1开始、SyncMirror 重新同步速度设置为默认值4、而先前设置为1。
- https://kb-cn.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Active_IQ_Wellness__Up_to_High_Impact_This_system_is_reporting_a_high_average_CPU_utilizationONTAP 9 Data ONTAP 8.2 7-模式 有关 如何通过命令行界面对ONTAP 9和Data ONTAP 7-模式验证CPU利用率的详细信息、请参见知识库文章 :Data ONTAP中的CPU利用率: 建议 Active IQ Unified Manager 监控性能。 工作负载延迟是可能出现的问题的最佳指标、因为它会随着系统负载的增加而增加。 使用 ActiveIQ 查看CPU随时...ONTAP 9 Data ONTAP 8.2 7-模式 有关 如何通过命令行界面对ONTAP 9和Data ONTAP 7-模式验证CPU利用率的详细信息、请参见知识库文章 :Data ONTAP中的CPU利用率: 建议 Active IQ Unified Manager 监控性能。 工作负载延迟是可能出现的问题的最佳指标、因为它会随着系统负载的增加而增加。 使用 ActiveIQ 查看CPU随时间变化的情况: 如果每个节点的CPU利用率始终高于60%(如果ONTAP版本为7-模式或9.6或更早版本)或每个节点的CPU利用率高于70%(如果ONTAP版本为9.7或更高版本)、则建议检查工作负载并将工作负载重新定位到不太繁忙的节点。 如果利用率是间歇性的或一次性的高峰、则除了持续监控之外、可能没有必要采取任何其他措施。 您可以使用 System Manager 或命令行界面移动卷。
- https://kb-cn.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/Active_IQ_Wellness_Risk_ONTAP_Antivirus_Connector_1_0_7_connections_repeatedly_disconnected-reconnected适用场景 ONTAP防病毒连接器1.0.7 CIFS 风险摘要 ONTAP防病毒连接器1.0.7可能会频繁断开和重新连接、这会导致发生原因延迟病毒扫描请求、并导致额外的CIFS操作延迟 本文档中介绍的最佳实践是、将ONTAP防病毒连接器升级到CAVSHIM-135的固定版本或实施所述的临时解决策。这有助于避免该错误可能导致的客户端访问问题。