跳转到主内容

OCSM 为什么无法识别 RTC 电池电量低的警告?

Views:
40
Visibility:
Public
Votes:
0
Category:
oncommand-unified-manager
Specialty:
OM
Last Updated:

适用场景

  • ONTAP 9
  • OnCommand System Manager ( OCSM )
  • FAS
  • AFF

问题解答

在 OCSM 中, RTC 电池电量不足警告事件未定义为通知事件。

追加信息

有关 [1] OCSM 的警报说明详细信息,请参见使用 System Manager 进行集群管理。

警报相关 领域摘录:
 
Alerts and Notifications
Displays all alerts in red, such as emergency EMS events, offline node details, broken disk details, license entitlements that are at high risk, and offline network port details. Displays all notifications in yellow, such as health monitor notifications that occurred in the past 24 hours at the cluster level, license entitlements that are at medium risk, unassigned disk details, the number of migrated LIFs, volume move operations that failed, and volume move operations that required administrative intervention in the past 24 hours.

如上所述, OCSM 警报会通知 " 紧急 EMS 事件,磁盘,网络和许可证 " 。
此外, RTC 电池事件严重性为 Error 。  这不是紧急情况。
黄色通知在集群级别通知警报。但 RTC 电池事件处于节点级别。

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.