无法访问单模式 VIF : VIF 状态报告单模式 VIF 已中断
状态信息
适用场景
Data ONTAP 7
问题描述
- 二级 VIF 状态显示为“
Broke
” - 在“
vif status
”输出中,“Strike Count
”表示“10 of 10
”:
vifSingle: 2 links, transmit 'none', VIF Type 'single_mode' fail 'default'
VIF Status Broke Addr_set
up:
member1: state up, since 08Apr2011 07:01:55 (3+01:49:14)
mediatype: auto-1000t-fd-up
flags: enabled
input packets 8818, input bytes 564352
output packets 110, output bytes 4620
output probe packets 70, input probe packets 0
strike count: 10 of 10
up indications 1, broken indications 0
drops (if) 0, drops (link) 0
indication: up at 08Apr2011 06:54:57
consecutive 266185, transitions 21
member2: state up, since 08Apr2011 07:01:54 (3+01:49:15)
mediatype: Enabled virtual interface
flags: enabled favored
input packets 0, input bytes 0
output packets 233, output bytes 11548
output probe packets 140, input probe packets 0
strike count: 10 of 10
up indications 1, broken indications 0
drops (if) 0, drops (link) 0
indication: up at 08Apr2011 07:01:55
consecutive 266185, transitions 1