跳转到主内容

使用7MTT迁移数据后、CIFS共享在集群模式下丢失

Views:
4
Visibility:
Public
Votes:
0
Category:
7-mode-transition-tool<a>7MTT</a><a>CIFS共享</a><a>2009-496375</a>
Specialty:
NAS
Last Updated:

适用场景

7模式过渡工具(7MTT)

问题描述

  • 在应用配置(预转换)阶段报告以下警告: 

  • 完成过渡后、不会将7-模式系统中的一个或多个CIFS共享迁移到集群模式系统。
  • 7MTT日志显示相同的警告、指出 CIFS服务器未在7-模式系统上运行

示例:

"messageTags" : [ ],
"miscTags" : [ ],
"message" : "The CIFS server is not running on the following 7-Mode storage systems. Therefore, the tool will skip CIFS prechecks and transition of CIFS configurations from these 7-Mode systems.",
"type" : "SERIOUS_WARNING",
"affectedResourceTypeReadableString" : "7-Mode Controllers",
"ignorable" : false,
"aptType" : null,
"code" : "20032",
"correctiveAction" : "To enable the 7-Mode Transition Tool to perform CIFS prechecks and transition CIFS configurations, start the CIFS service on the these 7-Mode storage systems by using the 7-Mode command: 'cifs restart'. See the KB articleKB8010390https://kb.netapp.com/support/index?page=content&id=8010390for more information.",

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.