使用7MTT迁移数据后、CIFS共享在集群模式下丢失
适用场景
7模式过渡工具(7MTT)
问题描述
- 在应用配置(预转换)阶段报告以下警告:
- 完成过渡后、不会将7-模式系统中的一个或多个CIFS共享迁移到集群模式系统。
- 7MTT日志显示相同的警告、指出 CIFS服务器未在7-模式系统上运行
示例:
"messageTags" : [ ],
"miscTags" : [ ],
"message" : "The CIFS server is not running on the following 7-Mode storage systems. Therefore, the tool will skip CIFS prechecks and transition of CIFS configurations from these 7-Mode systems.",
"type" : "SERIOUS_WARNING",
"affectedResourceTypeReadableString" : "7-Mode Controllers",
"ignorable" : false,
"aptType" : null,
"code" : "20032",
"correctiveAction" : "To enable the 7-Mode Transition Tool to perform CIFS prechecks and transition CIFS configurations, start the CIFS service on the these 7-Mode storage systems by using the 7-Mode command: 'cifs restart'. See the KB articleKB8010390https://kb.netapp.com/support/index?page=content&id=8010390for more information.",