AutoSupport 消息:机箱电源降级
状态信息
适用场景
- Data ONTAP 8.2.5 及更早版本
- 7-模式 Data ONTAP
问题描述
CHSPWR:System Notification from Filer1 (CHASSIS POWER DEGRADED: PSU1 12V is failed. PSU1 5V is failed. PSU1 3V is failed)
System
Notification from Filer1 (CHASSIS POWER DEGRADED: PSU1 12V is failed. PSU1 5V is failed. PSU1 3V is failed)
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 AC Failed
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 12V Failed
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 5V Failed
[Filer1: monitor.chassisPower.degraded:notice]: Chassis power is degraded:
AutoSupport message: Chassis Power Degraded
将发送以下 AutoSupport 消息:
SHELF_FAULT
CHASSIS POWER SUPPLY FAIL
CHASSIS POWER SUPPLY DEGRADED
CHSPWR:
System
Notification from Filer1 (CHASSIS POWER DEGRADED: sensor RTC Battery) WARNING
故障排除
全面的 MB 测试失败
ERROR ENV013858: sensor RTC Battery failed;
sensor failed to return to normal
measured: 2633mV; upperLimit: 3996mV; lowerLimit: 0mV;
FSE 弯曲夹子,用于固定电池以固定电池、并再次运行诊断程序、这次成功:
( RTC 电池) ..................................2800<3072 毫伏 <3500