DS212 盘架报告两个 PSU 上的 DC 故障
适用于
- ONTAP 9
- DS212 磁盘架
- IOM12
- 电源模块 (PSU)
问题
- AutoSupport 已检测到
"SHELF POWER INTERRUPTED"事件。 - 同一磁盘架上的两个电源单元(PSU)报告错误:
- 环境状态报告:
=== ENVIRONMENT ===Channel: 0aShelf: 2SES device path: local access: 0a.02.99Module type: IOM12B; monitoring is activeShelf status: critical conditionPower Supply installed element list: 1, 2; with error: 1, 2Power Supply information by element:[1] Serial number: PSQ094231902539 Part number: 114-00148+G1Type: 7DInput voltage: <N/A>Firmware version: 0112 Swaps: 0[2] Serial number: PSQ094231902542 Part number: 114-00148+G1Type: 7DInput voltage: <N/A>Firmware version: 0112 Swaps: -
storage show fault显示 PSU 是CRITICAL。=== STORAGE-FAULT ===Enclosure Status: criticalChannel: 0aShelf: 2Shelf Type: DS212-12Product Serial Number: SHJSG2343000296Module Type: IOM12BPower Supplies:Element Status Status Bytes Status Descriptions1: CRITICAL 02,00,00,F1 DC FAIL, OFF, RQSTED ON, FAIL2: CRITICAL 02,00,00,F1 DC FAIL, OFF, RQSTED ON, FAIL
- 外部机架电源和 PSU 电源线没有问题。
- 基板管理控制器(BMC)重新启动不会清除 PSU 状态。
- 接管和交还不会清除 PSU 状态。
- 重新拔插 PSU 1 和 PSU 2 不会清除状态。
- 重新拔插 PSU 后,PSU 警示灯亮起琥珀色。