跳转到主内容

计算节点上的vmnicX暂时关闭

Views:
29
Visibility:
Public
Votes:
0
Category:
netapp-hci<a>2008586799</a>
Specialty:
nas
Last Updated:

适用场景

NetApp HCI 计算节点

问题描述

vmnic2vmnic3一个计算节点上的或暂时关闭。

示例:

2020-12-12T13:34:24.285Z: [netCorrelator] 6777049499000us: [vob.net.dvport.uplink.transition.down] Uplink: vmnic2 is down. Affected dvPort: 1524/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 1 uplinks up. Failed criteria: 128
2020-12-12T13:34:24.285Z: [netCorrelator] 6777049499046us: [vob.net.dvport.uplink.transition.down] Uplink: vmnic2 is down. Affected dvPort: vdrPort/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 5 uplinks up. Failed criteria: 128
2020-12-12T13:34:24.285Z: [netCorrelator] 6777049499060us: [vob.net.dvport.uplink.transition.down] Uplink: vmnic2 is down. Affected dvPort: 1658/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 5 uplinks up. Failed criteria: 128
2020-12-12T13:34:24.285Z: [netCorrelator] 6777049499451us: [vob.net.vmnic.linkstate.down] vmnic vmnic2 linkstate down
2020-12-12T13:34:26.002Z: [netCorrelator] 6777059752759us: [esx.problem.net.dvport.redundancy.lost] Lost uplink redundancy on DVPorts: "1524/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6". Physical NIC vmnic2 is down.
2020-12-12T13:34:26.002Z: [netCorrelator] 6777059752926us: [esx.problem.net.dvport.redundancy.degraded] Uplink redundancy degraded on DVPorts: "vdrPort/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6", "1658/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6". Physical NIC vmnic2 is down.
2020-12-12T13:34:28.804Z: [netCorrelator] 6777054018733us: [vob.net.vmnic.linkstate.up] vmnic vmnic2 linkstate up
2020-12-12T13:34:28.906Z: [netCorrelator] 6777054120739us: [vob.net.dvport.uplink.transition.up] Uplink: vmnic2 is up. Affected dvPort: 1524/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 2 uplinks up
2020-12-12T13:34:28.906Z: [netCorrelator] 6777054120769us: [vob.net.dvport.uplink.transition.up] Uplink: vmnic2 is up. Affected dvPort: vdrPort/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 6 uplinks up
2020-12-12T13:34:28.906Z: [netCorrelator] 6777054120773us: [vob.net.dvport.uplink.transition.up] Uplink: vmnic2 is up. Affected dvPort: 1658/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 6 uplinks up
2020-12-12T13:34:30.002Z: [netCorrelator] 6777063752864us: [esx.clear.net.dvport.redundancy.restored] Uplink redundancy restored on DVPorts: "1524/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6", "vdrPort/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6", "1658/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6". Physical NIC vmnic2 is up recently
 
 
2020-12-12T13:34:23.340Z cpu32:2023481)ixgbe 0000:18:00.0: vmnic2: Received unrecoverable ECC Err,initiating reset.
2020-12-12T13:34:23.340Z cpu53:66203)ixgbe 0000:18:00.0: vmnic2: Reset adapter

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 