跳转到主内容

Quanta BMC 控制台重定向需要哪些端口

Views:
335
Visibility:
Public
Votes:
0
Category:
netapp-hci
Specialty:
hci
Last Updated:

适用于

  • NetApp H610S
  • BMC

回答

要允许 BMC 在 NetApp H610S 系列节点(Triton)上进行控制台重定向,请确保在防火墙中打开以下端口:

服务 协议 端口
SSH TCP 22
IPMI TCP / UDP 623
HTTP TCP 80
HTTPS TCP 443
远程控制台 TCP 7578
远程挂载映像 TCP 5120, 5122, 5123

 

 

追加信息

追加信息_text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.