计算节点的一个端口持续摆动
适用于
NetApp HCI (计算节点)
问题
esxcli network nic list
在计算节点上执行的命令将显示Link Status
为Down
和Speed
与0
摆动期间相同
- 交换机日志显示了摆动端口的端口 连接到的不断启动和关闭
011126: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to up
011129: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to down
011130: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to up
011133: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to down
011134: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to up
011135: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to down
vobd.log
文件显示Failed criteria: 128
了摆动端口的和关闭消息
<DATE TIME>: [netCorrelator] 2997223648873us: [vob.net.pg.uplink.transition.down] Uplink: vmnic3 is down. Affected portgroup: HCI_Internal_Storage_Management_Network. 1 uplinks up. Failed criteria: 128
<DATE TIME>: [netCorrelator] 2997223648874us: [vob.net.pg.uplink.transition.down] Uplink: vmnic3 is down. Affected portgroup: Management_Network. 1 uplinks up. Failed criteria: 128
<DATE TIME>: [netCorrelator] 2997223648971us: [vob.net.vmnic.linkstate.down] vmnic vmnic3 linkstate down
<DATE TIME>: [netCorrelator] 2997234550242us: [esx.problem.net.redundancy.lost] Lost uplink redundancy on virtual switch "vSwitch0". Physical NIC vmnic3 is down. Affected port groups: "HCI_Internal_Storage_Management_Network", "Management_Network", "HCI_Internal_Storage_Management_Network", "Management_Network"
hostd
日志文件显示启动和关闭消息
<DATE TIME> info hostd[2155779] [Originator@6876 sub=Vimsvc.ha-eventmgr] Event 12675 : Lost uplink redundancy on virtual switch "vSwitch0". Physical NIC vmnic3 is down. Affected portgroups:"HCI_Internal_Storage_Management_Network", "Management_Network", "HCI_Internal_Storage_Management_Network", "Management_Network".
<DATE TIME> info hostd[2208542] [Originator@6876 sub=Vimsvc.ha-eventmgr] Event 12679 : Uplink redundancy restored on virtual switch "vSwitch0", portgroups: "HCI_Internal_Storage_Management_Network", "Management_Network", "HCI_Internal_Storage_Management_Network", "Management_Network". Physical NIC vmnic3 is up.
vmkernel
日志文件显示启动和关闭消息
vmkernel.log:<DATE TIME> cpu14:2097827)ixgben: ixgben_CheckLink:2745: Link is down for device vmnic3 (0x4308a3c8f0c0)
vmkernel.log:<DATE TIME> cpu14:2097827)ixgben: ixgben_CheckLink:2745: Link is up for device vmnic3 (0x4308a3c8f0c0)