计算节点的一个端口持续摆动

Views:
42
Visibility:
Public
Votes:
0
Category:
netapp-hci
Specialty:
hci
Last Updated:

适用于

NetApp HCI (计算节点)

问题

  • esxcli network nic list 在计算节点上执行的命令将显示 Link StatusDownSpeed0 摆动期间相同

HCI_flapping_NIC.png

  • 交换机日志显示了摆动端口的端口 连接到的不断启动和关闭

011126: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to up
011129: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to down
011130: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to up
011133: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to down
011134: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to up
011135: .<DATE TIME>: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to down

  • vobd.log 文件显示Failed criteria: 128了摆动端口的和关闭消息

<DATE TIME>: [netCorrelator] 2997223648873us: [vob.net.pg.uplink.transition.down] Uplink: vmnic3 is down. Affected portgroup: HCI_Internal_Storage_Management_Network. 1 uplinks up. Failed criteria: 128
<DATE TIME>: [netCorrelator] 2997223648874us: [vob.net.pg.uplink.transition.down] Uplink: vmnic3 is down. Affected portgroup: Management_Network. 1 uplinks up. Failed criteria: 128
<DATE TIME>: [netCorrelator] 2997223648971us: [vob.net.vmnic.linkstate.down] vmnic vmnic3 linkstate down
<DATE TIME>: [netCorrelator] 2997234550242us: [esx.problem.net.redundancy.lost] Lost uplink redundancy on virtual switch "vSwitch0". Physical NIC vmnic3 is down. Affected port groups: "HCI_Internal_Storage_Management_Network", "Management_Network", "HCI_Internal_Storage_Management_Network", "Management_Network"

  • hostd 日志文件显示启动和关闭消息

<DATE TIME> info hostd[2155779] [Originator@6876 sub=Vimsvc.ha-eventmgr] Event 12675 : Lost uplink redundancy on virtual switch "vSwitch0". Physical NIC vmnic3 is down. Affected portgroups:"HCI_Internal_Storage_Management_Network", "Management_Network", "HCI_Internal_Storage_Management_Network", "Management_Network".
<DATE TIME> info hostd[2208542] [Originator@6876 sub=Vimsvc.ha-eventmgr] Event 12679 : Uplink redundancy restored on virtual switch "vSwitch0", portgroups: "HCI_Internal_Storage_Management_Network", "Management_Network", "HCI_Internal_Storage_Management_Network", "Management_Network". Physical NIC vmnic3 is up.

  • vmkernel 日志文件显示启动和关闭消息

vmkernel.log:<DATE TIME> cpu14:2097827)ixgben: ixgben_CheckLink:2745: Link is down for device vmnic3 (0x4308a3c8f0c0)
vmkernel.log:<DATE TIME> cpu14:2097827)ixgben: ixgben_CheckLink:2745: Link is up for device vmnic3 (0x4308a3c8f0c0)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.