跳转到主内容

SolidFire AIQ 事件 iSCSI 会话恢复计数增加意味着什么?

Views:
5
Visibility:
Public
Votes:
2
Category:
element-software
Specialty:
hci
Last Updated:

适用场景

NetApp Element 软件

问题解答

如果客户端配置不当,或者 2 个客户端配置了相同的启动程序 IQN 并尝试登录到相同的卷,则 iSCSI 会话恢复计数可能会增加。
另一个原因可能是,当客户端检测到故障并在目标检测到初始会话失败之前尝试重新登录时,由于争用情况而导致误报事件。因此,警报前的限制为每 60 分钟 200 次。

追加信息

AIQ事件详细信息 :
iSCSI session reinstatement count: 1583 exceeds limit of 200 every 60 minutes, potential causes: host configuration (duplicate initiator IQNs), etc. recent detail: initiator: x-x-x target: x-x-x
 
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.