问题
在计划的 CVO 升级期间,在节点接管(作为升级的一部分)之后,每个节点上的聚合进入降级状态并开始丛重新同步操作:
Error:Failed to upgrade the ONTAP with status: paused_on_error原因
- 升级过程中 AWS EBS/GCP 卷上的后端存储延迟
- CVO 检测到设备延迟超过 25,000 微秒阈值,导致磁盘被暂时标记为失败或丢失
- 这触发了聚合降级状态和丛重新同步,进而暂停升级,直到重新同步完成
Sun Oct 12 09:51:22 +0000 [CVO_CVO_Cluster: kernel: device.latency.threshold:notice]: The device latency in microseconds exceeded the threshold value for device "isp25" and the associated target device "/dev/nvd9". The threshold is "25000", execution latency is "26743", total latency is "26766", and the number of operations for this period is "69".Sun Oct 12 09:51:22 +0000 [CVO_Cluster: kernel: device.latency.threshold:notice]: The device latency in microseconds exceeded the threshold value for device "isp28" and the associated target device "/dev/nvd8". The threshold is "25000", execution latency is "25692", total latency is "25711", and the number of operations for this period is "70".解决方案
- 完成 plex 重新同步后,升级将继续,两个节点都应成功升级。
- 使用 plex show 命令检查 plex 重新同步的状态
合作伙伴备注
合作伙伴备注文本
追加信息
有关磁盘延迟的其他详细信息,请联系 AWS/GCP