适用场景
- NetApp云卷ONTAP (CVO) 9.7
- Microsoft Azure
问题描述
CVO处于故障状态、升级到ONTAP9.7P22后经常发生崩溃
- CVO工作环境错误:
Failed - Show Failure Message
Cloud Manager cannot communicate with Cloud Volumes
ONTAP because there is no connectivity or because the Cloud Volumes ONTAP system is not available.
- 崩溃的EMS日志:
Wed Jul 12 07:39:02 +0000 [nodename-01: nodewatchdog: nodewatchdog.node.panic:alert]: Data ONTAP has experienced a serious internal error: Process vldb unresponsive for 210 seconds. This might cause the node experiencing the problem to become unresponsive to data access. The node has been panicked to prevent this condition from continuing.
Wed Jul 12 07:39:02 +0000 [nodename-01: nodewatchdog: sk.panic:alert]: Panic String: Process vldb unresponsive for 210 seconds in process nodewatchdog on release 9.7P22 (C)
Wed Jul 12 07:39:02 +0000 [nodename-01: nodewatchdog: coredump.shutdown.trace:notice]: coredump shutdown times: kmod dumper start 7, panic_info set 14, sf_dumpcore sent 15, sparecore id sent 59, fmot_outage info sent 0, disk_dump_start done 0, coredump begin 24 (all in msec).