升级AWS CVO节点后无法执行接管
- Views:
- 8
- Visibility:
- Public
- Votes:
- 0
- Category:
- cloud-volumes-ontap-cvo
- Specialty:
- cloud<a>2009335170</a>
- Last Updated:
适用场景
- Cloud Volumes ONTAP ( CVO )
- Amazon Web Services ( AWS )
问题描述
- 已使用命令行界面开始CVO主要版本升级
- 第一个节点完成升级并执行部分交还
Storage failover show
显示takeover is not possible and each node is waiting on the other
Cluster::*> storage failover show
Takeover
Node Partner Possible State Description
-------------- -------------- -------- -------------------------------------
Node1 Node2 false Waiting for Node2, Partial
giveback, Takeover is not possible:
The version of software running on
each node of the SFO pair is
incompatible, Storage failover
interconnect error, NVRAM log not
synchronized, Disk inventory not exchanged
Node2 Node1 false Waiting for Node1, Partial
giveback, Takeover is not possible:
The version of software running on
each node of the SFO pair is
incompatible, Storage failover
interconnect error, NVRAM log not
synchronized, Disk inventory not exchanged
- 两个节点的RDMA互连均已关闭
Cluster::*> storage failover show -fields interconnect-links,interconnect-up,interconnect-type
node interconnect-up interconnect-links interconnect-type
-------------- --------------- ------------------------------------- -----------------
Node1 false RDMA Interconnect is down (Link down) MVIA-RDMA
Node2 false RDMA Interconnect is down (Link down) MVIA-RDMA
2 entries were displayed.
Cluster::*> ha interconnect status show
(system ha interconnect status show)
Node: Node1
Link Status: down
IC RDMA Connection: down
Node: Node2
Link Status: down
IC RDMA Connection: down
2 entries were displayed.