跳转到主内容

升级AWS CVO节点后无法执行接管

Views:
8
Visibility:
Public
Votes:
0
Category:
cloud-volumes-ontap-cvo
Specialty:
cloud<a>2009335170</a>
Last Updated:

适用场景

  • Cloud Volumes ONTAP ( CVO )
  • Amazon Web Services ( AWS )

问题描述

  • 已使用命令行界面开始CVO主要版本升级
  • 第一个节点完成升级并执行部分交还
  • Storage failover show 显示takeover is not possible and each node is waiting on the other

Cluster::*> storage failover show
                              Takeover
Node           Partner        Possible State Description
-------------- -------------- -------- -------------------------------------
Node1      Node2           false  Waiting for Node2, Partial
                                       giveback, Takeover is not possible:
                                       The version of software running on
                                       each node of the SFO pair is
                                       incompatible, Storage failover
                                  interconnect error, NVRAM log not
                                      synchronized, Disk inventory not exchanged
Node2      Node1           false  Waiting for Node1, Partial
                                       giveback, Takeover is not possible:
                                       The version of software running on
                                       each node of the SFO pair is
                                       incompatible, Storage failover
                                  interconnect error, NVRAM log not
                                      synchronized, Disk inventory not exchanged

  • 两个节点的RDMA互连均已关闭

Cluster::*> storage failover show -fields interconnect-links,interconnect-up,interconnect-type
node           interconnect-up interconnect-links                    interconnect-type
-------------- --------------- ------------------------------------- -----------------
Node1         false           RDMA Interconnect is down (Link down) MVIA-RDMA
Node2         false           RDMA Interconnect is down (Link down) MVIA-RDMA
2 entries were displayed.


Cluster::*> ha interconnect status show
  (system ha interconnect status show)

                       Node: Node1
                Link Status: down
         IC RDMA Connection: down

                       Node: Node2
                Link Status: down
         IC RDMA Connection: down
2 entries were displayed.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.