跳转到主内容

由于数据 LIF' 失败, CVO 升级失败 迁移

Views:
17
Visibility:
Public
Votes:
2
Category:
cloud-volumes-ontap-cvo
Specialty:
cloud<a>2008465762</a>
Last Updated:

适用场景

Cloud Volume ONTAP (CVO)

问题描述

由于数据LIF迁移失败、CVO升级失败。

示例

node::> cluster image show-update-progress                                          
                                                               
                       Estimated      Elapsed                             
Update Phase      Status           Duration     Duration                             
-------------------- ----------------- --------------- ---------------                             
Pre-update checks   completed         00:10:00     00:01:00                             
Data ONTAP updates   paused-on-error      01:32:00     19:57:18                             
                                                               
Details:                                                            
                                                               
Node name       Status       Status Description                                   
-------------------- ----------------- --------------------------------------                         
node-01       waiting                                                  
node-02       failed       Error: Failed to migrate data LIFs                           
                    from node "node-02".                                
                    Action: Migrate all of the data LIFs                         
                    using the "network interface                              
                    migrate-all -node node-02" command.                          
5 entries were displayed.                                                   
                                                               
Status: Paused - An error occurred in "Data ONTAP updates" phase. The update cannot continue until the error has been resolved. 
Resolve all issues, then use the "cluster image resume-update" command to resume the update.               

 
node::> network interface migrate-all -node node-02
Error: command failed: Failed to migrate one or more LIFs away from node "node-02". Use the "network interface show
    -curr-node node-02" command to review the status of any remaining LIFs on that node.
 
node::> event log show
Time         Node        Severity    Event
------------------- ---------------- ------------- ---------------------------
9/17/2020 02:26:58  node-02     ERROR      vifmgr.extRoute.noConn: Failed to verify connectivity with the mediator se
rver, IP 10.135.26.11 (error Failed to verify connectivity to the mediator. The system encountered a timeout waiting for the
 mediator to complete the operation. Retry the command. If the problem persists, contact technical support personnel for assi
stance.).
 
通过ASUP访问vifmgr.log
00000003.00192c6f 0e9d7d9e Thu Sep 17 2020 02:27:03 +00:00 [kern_vifmgr:info:8150] [0x808e43600] [FloatingIpMgrImpl::postOperationsToMediator] Failed to update external routing information; failed to send POST msg to mediator, URI: http://10.135.26.11:3080/v1/clusters/2911f4de-1987-11ea-a11d-111111/route_tables/update_all, request: {"IPs":[{"ip":"10.135.26.22","dest":"eni-0614d0e1b8a4a4a4","op":"replace"}]}, status: Timeout was reached, err: Failed to update external route tables for IP "10.135.26.22". The system encountered a timeout waiting for the mediator to complete the operation. Retry the command. If the problem persists, contact technical support personnel for assistance., server response:
 
 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.