CVO节点卡在启动报告设备延迟中
适用场景
- ONTAP 9
- Cloud Volumes ONTAP
问题描述
- 节点 启动需要很长时间。
- 在启动过程中未挂载Mroot
WARNING: netapp_mount_mroot: vol0 DSID is MISSING.
WARNING: netapp_mount_mroot: d-blade boot is incomplete.
netapp_mount_mroot: /mroot is not mounted, retrying...
netapp_mount_mroot: /mroot is not mounted, retrying...
- 启动期间会观察到磁盘延迟问题。
[node01:device.latency.threshold:notice]: The device latency in microseconds exceeded the threshold value for device "da7" and the associated target device "n/a". The threshold is "25000", execution latency is "101538", total latency is "101540", and the number of operations for this period is "638".
[node01:device.latency.threshold:notice]: The device latency in microseconds exceeded the threshold value for device "da9" and the associated target device "n/a". The threshold is "25000", execution latency is "99387", total latency is "99390", and the number of operations for this period is "664".