Cloud Insights Dell EMC VNX统一数据收集器失败、并显示"Inconsistent data reRetrieved:Error during parse of results from CLI"
适用场景
- Cloud Insights
- OnCommand Insight
- Dell EMC VNX统一数据收集器
问题描述
配置 Dell EMC VNX Unified Data Collector时、收集器失败、并显示错误Inconsistent Data retrieved
:/Error during parse of results from CLI
。
在录制 root/log_sample.log
文件中、出现类似以下内容的错误:
2023-01-11 09:47:38,298 ERROR [com.onaro.sanscreen.acquisition.framework.datasource.BaseDataSource] Collector_Name [Internal error] - Error parsing results from device, found error message: [The -User, -Password and -Scope security switches are required to complete a request. Omit these switches when using the stored values from the security file.] ([Device name General Device]: Error line: [The -User, -Password and -Scope security switches are required to complete a request. Omit these switches when using the stored values from the security file.], error pattern: [^The -User, -Password and -Scope security switches are required to complete a request\..*] found at line: [15])