适用场景

  • Astra Trident
  • ONTAP 后端
  • ONTAP 集群具有99个以上的联机数据LIF

问题描述

  • tridentctl get backend 由于""而失败command terminated with exit code 1

# ./tridentctl get backend  -d
Operating mode = tunnel, Trident pod = trident-csi-84c99f54d-v4psr, Namespace = trident, CLI = oc
Invoking tunneled command: oc exec trident-csi-84c99f54d-v4psr -n trident -c trident-main -- tridentctl --debug get backend
Operating mode = direct, Server = 127.0.0.1:8000, Autosuport server = 127.0.0.1:8003
Trident URL: http://127.0.0.1:8000/trident/v1
--------------------------------------------------------------------------------
Request Method: GET
Request URL: http://127.0.0.1:8000/trident/v1/backend
Request headers: map[Content-Type:[application/json]]
Request body:
................................................................................
Error: Get http://127.0.0.1:8000/trident/v1/backend: EOF
command terminated with exit code 1

  • tridentctl get backend 成功、但需要很长时间
  • 如果通过在 debugTraceFlags 后端定义中包含来启用后端的调试日志记录、则Trident控制器日志会显示 net-interface-get-iterAPI已重复调用

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.