适用场景

  • Astra三端
  • ONTAP SAN
  • RedHat

问题描述

卷挂载失败并显示以下错误、并且在挂载期间、存储和主机之间存在LUN序列号(Hex)差异。

TRIdent日志:

level=error msg="Failed to verify multipath device serial." logLayer=csi_frontend lunSerialNumber="818kK$V-9HdE" lunSerialNumberHex=3831386b4b24562d39486445 multipathDevice=dm-xx multipathDeviceUUID="mpath-3600a09803831386b455d562d51686279\n" requestID=a973efbe-94b4-4705-be37-246bba8deff8 requestSource=CSI workflow="node_server=stage"

level=debug msg="<<<< iscsi.AttachISCSIVolume" logLayer=csi_frontend requestID=a973efbe-94b4-4705-be37-246bba8deff8 requestSource=CSI workflow="node_server=stage"

level=debug msg="Attach iSCSI volume is not complete, waiting." error="multipath device 'dm-xx' serial check failed" increment=946.402806ms logLayer=csi_frontend requestID=a973efbe-94b4-4705-be37-246bba8deff8 requestSource=CSI workflow="node_server=stage"

level=error msg="GRPC error: rpc error: code = Internal desc = rpc error: code = Internal desc = failed to stage volume: multipath device 'dm-xx' serial check failed" logLayer=csi_frontend requestID=a973efbe-94b4-4705-be37-246bba8deff8 requestSource=CSI

存储的LUN输出:

::> lun show /vol/lun /lun <vol_name> 0 -field serial十六进制文件

Vserver                         路径                                                        串行十六进制
-----------------------        -------------------------------     -----------------------
SVM_Name              /vol/lN/l0/0 <vol_name>                                         3831386b4b24562d39486445

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.