跳转到主内容

Trident 是否需要 iscsid.conf 中的 "node.session.scan = manual"?

Views:
Visibility:
Public
Votes:
0
Category:
trident-kubernetes
Specialty:
snapx
Last Updated:

适用于

  • Trident
  • Trident SAN CSI 驱动程序(ontap-san、ontap-san-economy、solidfire-san)

回答

是的。node.session.scan = manual/etc/iscsi/iscsid.conf 中必须设置,以避免冲突,因为 Trident 会自动执行 LUN 扫描。

注:除非 NetApp 特别指示,否则不要执行手动 LUN 扫描。

追加信息

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.