在将Dm设备从22.07之前的版本升级到22.10或更高版本后、可以看到出现故障的dm设备
- Views:
- 9
- Visibility:
- Public
- Votes:
- 0
- Category:
- trident-openshift<a>200956772.</a>
- Specialty:
- snapx
- Last Updated:
适用场景
- Astra Trident
- 当前Asta三项功能版本为22.10或更高版本
- 以前的Asta三端安装版本为22.07或更早版本
- ONTAP SAN 后端
问题描述
- 升级到TRIdent版本22.10 (或更高版本)后、将显示以下影响:
| sddj: couldn't get target port group
| sdbv: couldn't get target port group
multipath -ll
显示了许多/dev/sd...
设备和多路径设备的以下信息:
3600a098038305654752b503177444141 dm-64 NETAPP ,LUN C-Mode
size=SIZE_IN_G features='3 pg_init_retries 50 retain_attached_hw_handler' hwhandler='1 alua' wp=rw
|-+- policy='round-robin 0' prio=0 status=enabled
| `- 3:0:0:45 sddj 71:16 failed faulty running
`-+- policy='round-robin 0' prio=0 status=enabled
`- 2:0:0:45 sdbv 68:144 failed faulty running
syslog
在节点上、底层磁盘设备也会显示以下错误:
multipathd[991]: 3600a098038305654752b503177444141: sddj - tur checker reports path is down
multipathd[991]: 3600a098038305654752b503177444141: sdbv - tur checker reports path is down