If you missed the pre-registration for NetApp MS Azure AD B2C Go Live, when you log in, the new login prompt will offer the option to register. Please note that access to your NetApp data may take up to 1 hour. Need assistance? Complete this form and select “Registration Issue” as the Feedback Category. 

Brocade 交换机端口会自动禁用

Views:
50
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

  • 所有 Brocade 交换机硬件平台
  • 所有 Brocade Fabric Operating System ( FOS )固件级别

问题描述

Brocade 交换机端口处于故障交换机状态会禁用此端口以防止发生摆动

示例:

errdump -a

WARNING, Brocade Fabric 1, Port 4 Faulted because of many Link Failures.
 
switchshow

  4   4   150400   --   N32    No_Module  FC  Disabled

sfpshow -all

RX Power:    -2.1    dBm (623.1uW)
TX Power:    -6.2    dBm (237.3 uW)

 