跳转到主内容
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

StorageGRID :如何对 " 节点关闭 " 警报进行故障排除

Views:
1
Visibility:
Public
Votes:
0
Category:
storagegrid
Specialty:
sgrid
Last Updated:

适用场景

NetApp 存储网格

问题描述

本文提供了有关 StorageGRID 中节点关闭事件的一般故障排除步骤。

可能会报告以下一个或多个错误:

  • NDDOWN:StorageGRID Notification from XXXXXX(NODE_DOWN-CRITICAL) ERROR
  • clipboard_eb959eb70f34a0a55fc7f4f711b3728c6.png网格管理器中的一个或多个 StorageGRID 节点会显示在蓝色图标( Disconnected – Unknown )旁边
  • Unable to communicate with Node 警报

 

对于所有 StorageGRID 版本,蓝色图标表示节点已断开连接,原因未知:

在此示例中,名为 DC1-S3 的存储节点具有一个蓝色图标。"Node Information" 面板上的 "Connection State" 为 "Unknown" , Unable to communicate with node 并且警报处于活动状态。

1089486-1.jpg

 

节点关闭事件的可能原因:

  • 维护操作,例如计划内重新启动或软件升级
  • 网络问题
  • 高工作负载(网格非常繁忙)的资源耗尽( CPU ,内存,磁盘) b/c
  • 硬件问题
  • 维护后管理布线不正确
  • VMware 控制台未响应

 