问题

  • 在 H610S 升级期间发生 FirmwareAbort 。

示例:

2020-11-04 02:08:17: Firmware 47%: Flashing firmware
2020-11-04 02:08:17: Warning: This step may take up to 30 minutes to complete. Do not interrupt the upgrade or power cycle the storage node during this step. Doing so may make the storage node unusable
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
2020-11-04 04:00:06: FirmwareAbort 47%: [UnhandledError pid=6719 cmd=return ${rc}]

  • VGA 控制台的输出将报告如下错误。

示例:

[2020-11-04T03:55:03Z] Failed cmd=("ipmitool""bmc""info") timeout="10s" exit_codes=("124""124""124""124"
...

[2020-11-04T03:57:21Z] CPLD Flashing Failed!

[2020-11-04T03:57:26Z] [UnhandledError pid=6719 cmd=return ${rc}]
 :: sfrtfi_firmware.sh:1843 | firmware_chassis_flash
 :: sfrtfi_firmware.sh:1918 | check_firmware
 :: init:142 | main

  • 节点将关闭。

 