适用场景

  • NetApp SolidFire SF 系列
  • Element 软件版本 12.2.0.777

问题描述

  • 节点意外关闭,未自动重新启动
  • iDRAC 显示错误CPU x(id) has an internal error (IERR)
  • ipmitool 从远程服务器(例如管理节点 VM )执行的命令确认断言的处理器错误:
    • 命令:ipmitool -H BMC_IP_ADDRESS -U bmc_username -I lan sel list
    • 输出示例:
      ID | DATE | TIME | Processor #0x60 | IERR | Asserted
    • 命令:ipmitool -H BMC_IP_ADDRESS -U bmc_username -I lan sel list -v
    • 输出示例:
      SEL Record ID : ID
       Record Type : 02
       Timestamp : DATE TIME
       Generator ID : 0020
       EvM Revision : 04
       Sensor Type : Processor
       Sensor Number : 60
       Event Type : Sensor-specific Discrete
       Event Direction : Assertion Event
       Event Data : 00ffff
       Description : IERR

 